Zirconium oxide Oxygen probes for continuous measurement of
O2-residue concentration in waste gas
Technical data
Standard length: 1000 mm
Diameter: 25 mm protection tube
Probe voltage: -10 ... 1000 mV
Thermo voltage: thermocouple type B
Measuring range: 0,0 ... 80,0 % O2
Operation temperature: 700 °C ... 1.500 °C
Measuring place: regenerator crown or waste gas channel, vertical position

Benefit
  • Economical use of energy by controlled low excess air: approx. 1,5 % energy saving potential, depending on conditions (in a combination with STG Lambda Control)
  • Controlled reliable near stoichiometric operation with O2 residue concentrations below 1 %, as requirement to reduce the NOX emission
  • Monitoring and control of air infiltration, e.g. reversal leakages, ingressed air
  • Monitoring and compensation of CO Peaks after reversal
  • Important: About 2 … 10% of combustion air results form uncontrolled air ingress, which is not detected by combustion air flow measurement!


    Delivery of complete Oxygen measurement system
  • Zirconium oxide Oxygen probe , type standard
  • Special measuring block needed (delivery on request)
  • Protection funnel, to use as heat protection and sensor rack
  • Signal cable junction box and coupling for reference air copper pipe
  • High temperature signal cable and reference air copper pipe
  • Reference air control boxes with:
    • Pump for ambient air or
    • Pressure regulator for compressed air
    • Air filter, microflowmeter and valves
  • Installation and start up

  • Signal processing
  • Advanced Signal Processing with continuous monitoring of O2, CO, Process value Lambda, Ingressed air - Patent EP 13169976.1
    • Separate signal processing unit mounted in local control box or
    • Implementation into existing Control System / Visualisation (Siemens, Allen-Bradley)
  • Automatical Lambda Control for optimisation of combustion
    Patent WO 2012/038482 A1
    • Identify air ingress
    • Minimize air ingress
    • Compensate air ingress
    • Analyze temperature footprint of air ingress XF

  • Options
  • Renting & Service Contract: Basic installation, regular services with maintenance of measurement incl. replacement of any sensors – renting from day 1
  • Annual Maintenance Contract: regular services with maintenance of measurement incl. replacement of any sensors (recommended: disclose with expiration of warranty period)